Beko BEMPE 090 Manual Del Usuario página 10

Aire acondicionado tipo partido gratis
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1
Safety instructions
• The appliance disconnection must be incorporated with an all-pole
disconnection device in the fixed wiring in accordance with the
wiring rules.
• Appliance shall be stored in a room without continuously operating
open flames (for example an operating gas appliance) and ignition
sources (for example an operating electric heater).
• Appliance shall be installed, operated and stored in a room with
a floor area larger than X m² (Please see the following form). The
appliance shall not be installed in an unventilated space, if that
space is smaller than X m² (Please see the following form).
Model (Btu/h)
≤30000
≤30000
≤30000
30000-48000
30000-48000
30000-48000
>48000
>48000
>48000
10 / 172 EN
Amount of
refrigerant to be
charged (kg)
≤2.048
≤2.048
≤2.048
2.048-3.2
2.048-3.2
2.048-3.2
>3.6
>3.6
>3.6
Free match split type air conditioner / User Manual
Maximum
installation
height (m)
2.2m
1.8m
0.6m
2.2m
1.8m
0.6m
2.2m
1.8m
0.6m
Minimum
room area
(m²)
4
4
35
7
10
80
9
13
80

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Bempe 120Bempf 181Bempf 271

Tabla de contenido