Maintenance notice
Recovery:
1. The clearance of refrigerants in the system is required when repairing or scrapping the appliance. It
is recommended to completely remove the refrigerant.
2. Only a special refrigerant tank can be used when loading the refrigerant into the storage tank.
Make sure the capacity of the tank is appropriate to the refrigerant injection quantity in the entire
system. All tanks intended to be used for the recovery of refrigerants should have a refrigerant
identification (i.e. refrigerant recovery tank). Storage tanks should be equipped with pressure relief
valves and globe valves and they should be in a good condition. If possible, empty tanks should be
evacuated and maintained at room temperature before use.
3. The recovery equipment should be kept in a good working condition and equipped with equipment
operating instructions for easy access. The equipment should be suitable for the recovery of R32
refrigerants. Besides, there should be a qualified weighting apparatus which can be normally used.
The hose should be linked with detachable connection joint of zero leakage rate and be kept in a
good condition.
Before using the recovery equipment, check if it is in a good condition and if it gets perfect
maintenance. Check if II electrical components are sealed to prevent the leakage of the refrigerant
and the fire caused by it. If you have any question, please consult the manufacturer.
4. The recovered refrigerant shall be loaded in the appropriate storage tanks, attached with a
transporting instruction, and returned to the refrigerant manufacturer. Don't mix refrigerant in
recovery equipment, especially a storage tank.
5. The space loading R32 refrigeration can't be enclosed in the process of transportation. Take anti
electrostatic measures if necessary in transportation. In the process of transport, loading and
unloading, necessary protective measures must be taken to protect the air conditioner to ensure
that the air conditioner is not damaged.
6. When removing the compressor or clearing the compressor oil, make sure the compressor
is pumped to an appropriate level to ensure that there is no residual R32 refrigerants in the
lubricating oil. The vacuum pumping should be carried out before the compressor is returned to the
supplier. Ensure the safety when discharging oil from the system.
Free match split type air conditioner / User Manual