How To Perform Measurements; Cabling Test - HT QuickLAN 6055 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. HOW TO PERFORM MEASUREMENTS

5.1.

CABLING TEST

The cable is tested in accordance with its defined cabling layout.
To test a cable:
1. Select the type of cable under test (paragraph 4.1.3).
2. Connect the cable under test to QuickLAN and to the remote unit (if necessary through
patch cables). The remote unit must be necessarily connected to the other end of the
cable being tested, otherwise no measurement is performed.
GO
3. Press
to perform all tests related to the selected type of cable.
If cabling is correct, a screen like this is displayed (OK).
The identification number (02) refers to the remote
identifier connected to the other end of the cable being
tested.
If cabling is not correct, a screen like this is displayed
(NOT OK). Referring to this example, "FAULT 1/3"
means that the detected errors are 3, of which the first
one is currently displayed. Details on the detected error
are given on the left side: the couple 1-2 is open. By
pressing
and
remaining screens and display other cabling errors
("FAULT 2/3", "FAULT 3/3").
QuickLAN 6055 detects all possible cabling errors detailed below.
It's indispensable to select the right type of cable. If UTP is selected although
a STP cable is tested, test results may be not reliable due to the shield
affecting the measurement.
it's possible to run over the
EN - 6
CAUTION
QuickLAN 6055

Publicidad

Tabla de contenido
loading

Tabla de contenido