Gas Pressure; Electrical - HeatStar HSRR30SP(LP) Instrucciones De Operacion Y Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE:
1.­­ O nly­Use­A­Pipe­Compound­Which­Is­Resistant­To­Liquefied­
Gases­On­L.P.­Installations.
2.­Fittings­Shown­Are­Not­Included­With­Heater.
BURNER
REFLECTOR
SIDE VIEW
Figure 3. Typical Piping Installation
Table 1
BTU/HR.­RATING
MODEL­NO.
NATURAL
HSRR30SP
30,000
HSRR40SP
40,000
The­clearances­to­combustibles­represent­a­surface­temperature­of­90°F­(32°C)­above­room­temperature.­Building­materials­with­low­
heat­tolerance­may­be­subject­to­degradation­at­lower­temperatures.­It is the installers responsibility to assure that adjacent materials are
protected from degradation.­­
Table 2
BTU/HR.­RATING
MODEL­
GAS
NO.
NATURAL
HSRR30SP
30,000
HSRR40SP
40,000
Enerco Group, Inc. |Gas-Fired Infra-Red Space Heaters
392929_HSRR30-2017-WO-V9.indd 4
FLEXIBLE GAS
LINE TO HEATER
PIPE NIPPLE
½ PSI MAX.
SHUT-OFF VALVE
TEE
DRIP LEG
CAP
GAS VALVE/
CONTROLLER
NORMAL­
GAS
MOUNTING­
POSITION
PROPANE
30,000
Horiz.-45°
40,000
Horiz.-45°
GAS SUPPLY PRESSURE (W.C.)
MIN.
PROPANE­ ­
NAT.
L.P.
30,000
6.6"
11"
40,000
6.8"
11"

6. GAS PRESSURE

When­a­higher­than­the­maximum­recommended­
gas­pressure­is­being­maintained­at­the­main­gas­
line,­a­separate­regulator­must­be­installed­ahead­of­
the­heater.­Refer­to­Table­2­for­maximum­allowable­
pressure­for­stated­model­and­gas.
See­heater­rating­plate­for­minimum­gas­supply­
pressure­"For­the­Purpose­of­Input­Adjustment"
On­a­multiple­heater­installation­it­may­be­possible­
to­use­one­large­capacity­regulator­or­an­individual­
regulator­for­each­heater.­Nevertheless,­it­is­
recommended­practice­to­make­the­entire­pipe­system­
a­loop.­Contact­your­local­representative­or­the­factory­
for­proper­gas­pressure­reducing­design­stage.
WARNING:
DO­NOT­EXCEED­½­P.S.I.­(14"­W.C.)
INLET­PRESSURE­TO­HEATERS­AS­SHOWN­IN­­FIGURE­3­
AND­TABLE­2

7. ELECTRICAL

All­external­wiring­must­be­in­accordance­with­the­
existing­electrical­code.­Use­wiring­diagram­furnished­
with­heater.­Be­sure­electric­supply­characteristics­
match­those­called­for­on­the­name­plate.­The­unit­
must­be­electrically­grounded­in­accordance­with­the­
National­Electrical­Code,­ANSI/NFPA70,­latest­revision.­
In­Canada­refer­to­Canadian­electrical­code­CSA­C22.1
CLEARANCES TO COMBUSTIBLES
TOP
SIDES
30"
30"
34"
30"
MAX.
MANIFOLD
NAT.
L.P.
NAT.
14"
14"
5.6"
14"
14"
5.8"
E4
Operating Instructions and Owner's Manual
BACK
BELOW
30"
54"
30"
68"
ORIFICE­SIZE
L.P.
NAT.
L.P.
10"
43
52
10"
37
49
7/13/17 12:24 AM

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hsrr30sp(ng)Hsrr30splp

Tabla de contenido