1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.

5. Before starting the equipment

It is recommend for the power supply to this ma-
chine either to be connected via a residual current
device circuit-breaker, which interrupts the power
flow as soon as the leakage current to earth ex-
ceeds 30 mA for 30 ms, or for it to be equipped
with an earth tester.
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Warning!
Always pull the power plug before making
adjustments to the equipment.
5.1 Using the equipment correctly
The pressure cleaner must be stood on a le-
vel, stable surface.
It is recommended that you adopt the correct
operating position every time you use the
equipment, with one hand on the gun and the
other on the lance.
Never direct the water jet at electrical lines or
the equipment itself.
So that the pump does not suffer any damage
when it is not in use, a small amount of leaka-
ge from the pump is normal.
Never use the machine in potentially explosi-
ve areas under any circumstances!
The operating temperature must be between
+5 and + 40°C.
Do not cover or modify the lance or the spray
nozzles in any way.
The pressure cleaner is designed to be used
with cold or lukewarm water (max. 40 °C); hig-
her temperatures can damage the pump.
Do not use water that is dirty, gritty or con-
tains any chemical products, as these could
impair operation and shorten the life of the
equipment.
Caution: Risk of explosion
Do not spray flammable liquids.
Anl_SA_TC_HP_90_SPK8.indb 30
Anl_SA_TC_HP_90_SPK8.indb 30
GB
Warning
Water that has passed through the non-return
valve is not drinkable.
Warning
If cleaning agent gets into contact with your skin
or into your eye, rinse immediately with lots of
clean water. Then consult a doctor or follow the
steps described on the safety data sheet or provi-
ded by the manufacturer of the cleaning agent.
5.2 Assembly
5.2.1 Assembling the equipment (Fig. 4a-4c)
Assemble the pressure cleaner as shown in Figu-
re 4a-4c.
5.2.2 Fitting the gun attachments (Fig. 3)
Various attachments can be fitted to the gun. First
fit the extension (6) to the gun (5). Then you can
press the attachments into the extension (you will
encounter a slight spring resistance) and secure
the attachment by turning.
Important! Check that the attachment is secure
before you begin with the cleaning.
Solid cone / flat fan lance (7)
The shape of the water jet can be changed from
solid cone to flat fan by turning nozzle (a) (Fig. 7).

5.2.3 Connecting the high-pressure hose

(Fig. 5a-5b)
Connect the high-pressure hose (8) to the gun (5)
and to the connector for the high-pressure hose
(13).
5.2.4 Water inlet connector (Fig. 6)
The connection for the water inlet (3) is equipped
with a connector (9) for standard hose coupling
systems. Plug the hose coupling on the supply
hose (min. Ø 1/2" / approx. 13 mm) to the water
inlet connector (9).
Always use a reinforced hose with a standard
coupling for the water inlet. The hose should be at
least 6 m in length. (Not supplied)
A backflow preventer must be installed between
the drinking water and the pressure cleaner! Ask
your local plumber about this.

5.2.5 Electrical connections

Before you connect the equipment to the
power supply make sure that the data on the
rating plate are identical to the supply voltage.
If you use any extension cables, make sure