DIP S2
DIP 1
DIP 2
DIP 3
DIP 4
0
0
0
0
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
0
0
0
0
1
1
0
0
1
0
1
0
1
1
1
0
1
0
0
1
1
1
0
1
1
0
1
1
1
1
1
1
1
Example 1 - Selective intercom
on a monitor with user code 1 and intercom address 1, P3 programming =
selective intercom with address 2, P4 = selective intercom with address 3.
Example 2 - KIT intercom (intercom between 2 contiguous addresses in
the range from 1 to 30, with the fi rst being an odd number):
on a monitor with user code 1, P3 programming = general internal call, P4
= two-family intercom with address 2.
1. Set S2 DIP switch 5-6 to the combination 01.
» the LED (green) fl ashes.
2. Refer to the table on page 27 and select a combination in which the
intercom function (INT or INTb) is listed for the buttons you wish to
program.
E.g. 1: for P3= single-family intercom, set S2 DIP switches 1-2-3-4 to the
combination 1000 or 0011 or 1011 (P3=INT), set S1 with address 2 in
accordance with table B on page 26, go to point 3.
E.g. 1: for P4= selective intercom, set S2 DIP switches 1-2-3-4 to the
combination 1110 or 1011 (P4=INT), set S1 with address 3 in accordance
DIP S2
DIP 1 DIP 2 DIP 3 DIP 4
P1
0
0
0
0
CCS
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
0
0
0
0
1
CCS
1
0
0
1
0
1
0
1
CCP
1
1
0
1
PAN
0
0
1
1
1
0
1
1
0
1
1
1
NULL
1
1
1
1
A
Lock- release
Speech
AI
Self-ignition
Main switchboard call
CCP
Example:
on a monitor with user code 5, P5 programming = self-ignition, P6 =
switchboard call.
1. Set S2 DIP switch 5-6 to the combination 01.
» the LED (green) fl ashes.
2. Refer to the table on page 27 and select a combination in which the
desired/necessary functions are listed for the buttons you wish to
program.
E.g.: for P5= self-ignition, P6= switchboard call, set S2 DIP switches 1-2-
3-4 to the combination 0011 (P5=AI, P6=CCS).
Programming buttons for intercom call
A
P1
P2
INT
INT
A
INTb
INT
INTb
INT
INT
Programming buttons for other functions
P2
A
AI
AI
A
AI
CCS
AI
D
PAN
A
K
CCS
K
CCP
D
NULL
NULL
NULL
CCS
K
D
PAN
with Art. 6433, 6434
P3
P4
INT
INTb
INTb
INT
INT
INT
INT
PROG
with table B on page 26, go to point 3.
E.g. 2: for P3= general internal call and P4= two-family intercom, set S2
DIP switches 1-2-3-4 to the combination 1000 (P3=INT, P4=INTb), set S1
with user code 1 in accordance with table A on page 24, go to point 3.
3. Press and release the button to be associated with the function.
» the LED (green) lights up.
» confi rmation tone in handset.
4. To exit programming mode, set S2 DIP switches 5-6 to the combination
00.
» the LED (green) switches off.
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the
combination 1111. Restore the user code setting on S1, see table
A on page 24.
with Art. 6433, 6434
P3
P4
D
CCP
PAN
CCS
CCP
K
CCS
AI
D
AI
PAN
CCP
PAN
CCS
K
NULL
NULL
PROG
Legend
Switchboard call
Guardian door-entry phone
call
Doctor
Panic
3. Press and release the button to be associated with the function.
» the LED (green) lights up.
» confirmation tone in handset.
4. To exit programming mode, set S2 DIP switches 5-6 to the combination 00.
» the LED (green) switches off.
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the
combination 1111.
DIP S1
P5
P6
INTb
ADDRESS
INTb
INT
INTb
INT
INT
INT
INT
P5
PAN
D
CCS
K
CCP
PAN
AI
AI
NULL
No function
NULL
PROG
Programmed functions
P6
K
CCS
CCP
D
PAN
D
AI
D
CCS
NULL
27
27