Internal Capacities
Total capacity
DE0041 / EV0041 ------------------------------------------------------------------------------- 3.6 cubic feet
DC0061 / DE0061 / EV0061 ------------------------------------------------------------------ 7.0 cubic feet
Controls
Type ------------------------------------------------------------------------------------------------------ Electronic
ON/OFF / TEMP SET switches ---------------------------------------------------------------------- Manual
Temperature setting range ------------------------------------------------- 0=OFF, 1=cold to 5=coldest
Temperature sensing devices -----------------------------------------------------Capillary Tube Sensor
Off-level Operating Limits
Side-to-side ----------------------------------------------------------30 degrees maximum at refrigerator
Front-to-back --------------------------------------------------------30 degrees maximum at refrigerator
Voltage Requirements
DE0041, DE0061,EV0041, EV0061, DC0061
12 VDC / 24 VDC
Minimum (cut-out) -------------------------------------------------------------------10.9 VDC / 23.8 VDC
Restart (cut-in) -----------------------------------------------------------------------12.2 VDC / 25.2 VDC
Maximum ------------------------------------------------------------------------------17.0 VDC / 31.5 VDC
Fuse ---------------------------------------------------------------------------------------------------------- 15 A
EV0041, EV0061
220 VAC
Nominal --------------------------------------------------------------------------- 205 - 253 VAC, 49/51 Hz
Minimum ------------------------------------------------------------------------------------------------- 90 VAC
Maximum ---------------------------------------------------------------------------------------------- 267 VAC
DE0041, DE0061
120 VAC
Nominal --------------------------------------------------------------------------- 108 - 132 VAC, 59/61 Hz
Minimum ------------------------------------------------------------------------------------------------- 90 VAC
Maximum ---------------------------------------------------------------------------------------------- 267 VAC
Current Draw
Fan ---------------------------------------------------------------------------------------------------------- 150 mA
Interior light / Divider Heater (DC / DE / EV0061 only) -------------------------------- 0.66 A / 0.20 A
Refrigerator:
12.8 VDC / 24 VDC
Startup ------------------------------------------------------------------------------------------------ 8 A / 4 A
Stabilization at 70°F Ambient --------------------------------------------------------------- 6.5 A / 3.1A
120 VAC / 240 VAC
Stabilization at 70°F Ambient --------------------------------------------------------------- 0.8 A / 0.4A
www.norcold.com
SPECIFICATIONS
5