Break-In Period; Frequency Of Use; Before Starting The Generator; Starting The Engine - Westinghouse iGen2200 Manual De Usuario

Generador inversor digital
Ocultar thumbs Ver también para iGen2200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION

BREAK-IN PERIOD

For proper break-in, do not exceed 50% of the rated
running watts (iGen2200: 900 watts / iGen2500: 1100
watts) during the first five hours of operation.
Vary the load occasionally to allow stator windings to heat
and cool and help seat the piston rings.

FREQUENCY OF USE

If the generator will be used on an infrequent or intermittent
basis (more than one month before next use), refer to the
Storage section of this manual for information regarding
fuel deterioration.

BEFORE STARTING THE GENERATOR

Verify that:
• The generator is placed in an safe, appropriate location.
• The generator is on a dry, flat, and level surface.
• The engine is filled with oil.
• Gasoline is in the fuel tank.
• All loads are disconnected.
• The ECO switch is in the OFF position.
Fire and explosion hazard. DO NOT move or tip the
generator during operation.

STARTING THE ENGINE

1. Turn the fuel cap vent to the ON position (iGen2200
only).
2. Turn the fuel switch to the choke position.
OFF
Note: The generator can be started from the Run position
if warm from operation.
DANGER
RUN
CHOKE
3. Firmly grasp and pull the recoil handle slowly until you
feel increased resistance, then pull rapidly.
4. After the engine starts, turn the fuel switch to the RUN
position.

STOPPING THE ENGINE

1. Turn off and unplug all connected electrical loads.
Never start or stop the generator with electrical devices
plugged in or turned on.
2. Let the generator run with no load for several minutes
to stabilize internal temperatures of the engine and
generator.
3. Turn the fuel switch to the OFF position.
4. Allow the engine to cool, then turn the fuel cap vent to
the OFF position (iGen2200 only).
Note: If there is an emergency and the inverter must be
stopped quickly, immediately move the fuel switch
to the OFF position.
Westinghouse Outdoor Power Equipment, LLC | 13
OFF
RUN
CHOKE

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Igen2500

Tabla de contenido