(Optional); Cooler Unit Connection; Installation On 2/4 Wheels Trolley - Sol Welding INOXA Serie Manual De Instrucciones

Ocultar thumbs Ver también para INOXA Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Instruction Manual
8.4
COOLER UNIT
CONNECTION (OPTIONAL)
Warning! Before the installation, it is necessary to make
sure the generator is not connected to the net.
NOTE: the following numbers refer to Fig. 2 to Page 5.
1.
Remove the adhesive from the panel
OUTPUT
COOLER UNIT
door (22).
SEE INSTRUCTION MANUAL
FOR INSTALLATION
2.
Open the two wholes on the panel
door and fix the cable holders, given
with the package, to the cooling unit.
3.
Open the panel door (22) by
unscrewing the screws (22A).
4.
Pass the cable (26) and (27) into the
cable holder.
5.
Remove the jumper from the "FLOW
SWITCH" clamps.
6.
Connect the cable (27) AC 400V, to
the clamps "400V", "0V" and "
NOTE WELL: the earth wire (Yellow
YELLOW
GREEN
Green) must be connected to the
right clamp.
7.
Connect the cable (26) (flowmeter
water signal) to the "FLOW SWITCH"
clamps.
8.
Fix the cable holder and close the
panel door (22).
8.5

INSTALLATION ON 2/4 WHEELS TROLLEY

(OPTIONAL)

TROLLEY 08
2 WHEELS
32
28
30-31
29
".
32
31
29
30
33
INOXA SERIES
TROLLEY 08
4 WHEELS
NOTE: for the assembling of the Trolley
refer to the instructions inside the packa-
ges of the Trolley.
1.
Place the MACHINE and the
COOLER UNIT on the designated
compartment (30-31).
2.
Fix the MACHINE and the COOLER
UNIT with the jack belt (28) on
the 2 wheels TROLLEY, with the
screws (33) on the 4 wheels Trolley.
3.
Place the gas cylinder on the designa-
ted compartment (29).
4.
Fix the GAS cylinder with the
chain (32).
GB
GB
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Inoxa 250 hfInoxa 360 hfInoxa 250 hfpInoxa 360 hfp

Tabla de contenido