Sol Welding INOXA Serie Manual De Instrucciones página 37

Ocultar thumbs Ver también para INOXA Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Instruction Manual
8.15 REMOTE CONTROL REGULATION
NOTE: numbers shown below are referring to Fig. 1-2 chapter 6
COMMANDS DESCRIPTION to Page 4-5.
The welding current can be regulated from a distance in the TIG
mode using the MANUAL or FOOT remote control.
a) MANUAL remote control connection:
1. For the connection use the
MANUAL REMOTE CONTROL ADAPTER
cod. V15190KI
B
Tig torch
2. Connect the 7 poles plug of the remote control and the plug of
the button of the torch to the adapter, see (A) and (B) on fig.
3. Connect the 7 poles plug (C) of the adapter to the socket (15)
of the machine. The display will flash for a few seconds.
4. Set the welding current using the remote control.
NOTA: the welding current is regulated from the minimum current
Manual
C
Remote
Control
A
of the machine to the set current on the display.
Ex. If the I2 set current is 200A, the regulation will be from 5A to
200A.
b) FOOT remote control connection:
1. Connect the 7-pin Plug of the remote
control to the Receptacle (15).
The display will blink for a few seconds.
2. Press the foot remote control to ignite
the welding arc and press it further to re-
gulate the current.
NOTA: the welding current is regulated
from the minimum current of the machine
to the set current on the display.
Ex. If the I2 set current is 200A, the regu-
lation will be from 5A to 200A.
c) Automatic system connection:
5
RELAY
MAX 1A
6
ROBOT
INOXA SERIES
On pin 5 and 6 of the 7 pin socket
there is the ARC ON signal.
The pins are shortcircuited by a
relay when the current is higher
then 3 amps with wich it is possible
to command a second party, such
as: rotative table, welding positio-
ner, robot etc.
17
GB
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Inoxa 250 hfInoxa 360 hfInoxa 250 hfpInoxa 360 hfp

Tabla de contenido