Up Slope And Down Slope Regulation; Timer Setting (Only On Hfp Series) - Sol Welding INOXA Serie Manual De Instrucciones

Ocultar thumbs Ver también para INOXA Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Instruction Manual

8.9 UP SLOPE AND DOWN SLOPE REGULATION

NOTE: numbers shown below are referring to Fig. 1-2 chapter 6
COMMANDS DESCRIPTION to Page 4-5.
In the TIG modality it is possible to set the "UP SLOPE" time and
the "DOWN SLOPE" time.
The "UP SLOPE" time, is not adjustable on INOXA HF series.
6
10
7
The DOWN SLOPE or UP SLOPE
times are adjustable from 0 sec to
10 sec.
On INOXA HF series
1. Turn the knob (6) to set
the "DOWN SLOPE" time.
2. The time will be showed
on the display for a few se-
conds.
It is adjustable from 0,1 se-
conds to 12.5 seconds.
On INOXA HFP series
1. Press the pushbuttons
(10) until the LED (11C) or
(11E) flashes.
2. With the knob (7) set the
"DOWN SLOPE" or "UP
10
SLOPE" ramp time.
3. The times will be showed
on the display. To exit from
the setting mode and con-
firm the value press the
knob (7).
8.10 TIMER SETTING (Only on INOXA HFP series)
NOTE: numbers shown below are referring to Fig. 1-2 chapter 6
COMMANDS DESCRIPTION to Page 4-5.
In the TIG modality it is possible to select the TIMER cycle.
This cycle allows the welding in tacking system or in timed system.
Pressing the button of the torch, after the pre-gasification phase,
the machine will reach the welding current and this will least for the
selected time with the Timer on parameter.
NOTE: the TIMER cycle can be used only in TIG 2 Times modali-
ty. See page 11.
7
To deactivate the TIMER cycle, repeat the points 1 and 2, turn the
knob (7) counter-clockwise until the displays shows 0,0.
The LED TIMER (14) will stay OFF.
NOTE: it is possible to memorize new settings in one of the avai-
lable JOBS. See page 16.
INOXA SERIES
1. Press the pushbuttons
(10) until the LED TIMER
(14) flashes.
2. Whith the knob (7) set the
Timer time.
3. The time will be showed
10
on the display. To exit from
the setting mode and to con-
firm the value, press the
knob (7).
The time is adjustable from
0,0 sec to 60 sec.
13
GB
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Inoxa 250 hfInoxa 360 hfInoxa 250 hfpInoxa 360 hfp

Tabla de contenido