Post Gas Time Setting (Only On Inoxa Hf Series) - Sol Welding INOXA Serie Manual De Instrucciones

Ocultar thumbs Ver también para INOXA Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Instruction Manual
B) JOB SAVING.
After having done the setting of one or more parameters, it is pos-
sible to memorize them in one of the available JOBS. It is possible
to memorize also working cycle such as: 2 or 4 Times cycle, timer,
pulsation, o electrode modality.
7
Push > 2 sec
7
Push > 2 sec
16
GB
1.
Press the knob (7) for
about 2 sec.
2.
The display will show:
"MEM JOB".
The LED JOB (9A) will flash.
3. Select the JOB from 1 to
10 by turning the knob (7).
E.g. JOB n° 7
4. Press again the knob (7)
for about 2 sec. to memorize
the JOB.
5. The LED JOB (9A) will
stay ON.
6. To exit the job modality
press the pushbutton (9)
until the LED (9A) turns
OFF.
8.14 POST GAS TIME SETTING
(Only on INOXA HF series)
NOTE: numbers shown below are referring to Fig. 1-2 chapter 6
COMMANDS DESCRIPTION to Page 4-5.
It is possible to modify the synergy value of the POST GAS time, to
adapt it to specific needs. For example, in a spot welding cycle the
time results too much long and it is needed to be shortened.
8
7
8
7
INOXA SERIES
1. Set the knob (7) on half
scale.
2. Turn ON the machine
and press the pushbutton
TEST GAS (8) within 1-2
sec.
3. On the display it will
appear the writing "REG
GAS" followed by "0".
4. With the knob (7) set the
percentage of the POST
GAS time reduction.
E.g. - 50%, the display will
show "- 5".
5. Turn clockwise to incre-
ase and counter-clockwise
to decrease.
A variation from 0 to +/- 90%
is possible.
6. Press the pushbutton (8)
to confirm the setting.

Publicidad