The fresh air inlet should have the minimum of 80cm² section and if there are more equipments
that use room air, the section must be increased. With all the equipments working, the differential
pressure between the interior and the exterior should not be greater than 4Pa.The air inlet
should be placed near the stove floor level and protected by a grate.
EN

Installation place

The stove installation should be done by specialized technical.
Complying with national and regional security and installation standards and regulations.
When the stove is installed inside a house all exhaust gases pipes should be completely sealed.
Use a proper and approved pellet vent pipe with silicone sealing.
The stove should not be dragged over an unprotected floor.
If the floor is made from combustible materials, the installation place of the stove should be
protected with a non-combustible materials. It should also protect the area near the door
avoiding falling hot pellets. The stove should be installed in a floor with capacity to support its
weight, if this is not possible use a base to equally distribute the weight of the stove.
Respect the security distances to combustible materials as well as the necessary distances
for maintenance.
Place the stove considering the hot air outlet of the equipement providing the best distribution
of the heat to the room.

Electrical connection

The stove should be connected to a power supply of 230V AC (50Hz) with short-circuit and
overload protection.
A cable type Schuko is supplied to connect the stove to the power supply.
The stove power plug has one fuse for protection.
EN // 79