Malfunctions
Probe
EN
Ignition Blocked
Link Error
Cleaning
Time/Clock blinking
Malfuntions or anomalies do not cause the shutdown of the stove.
To turn off the stove, in case of an emergency, you should do the normal shut down procedure.
To do this, you should press the OFF button for 3 seconds and allow the deactivation until OFF
appears on the display.
Alarm list
All alarms originate the deactivation of the stove with the information off the correspondant
error and activation of the alarm LED. It will be necessary to "reset" the alarm and restart. To
"reset" the stove, press "On/Off" for 3 to 4 seconds until a beep sound, and a message appears
on the display "reset alarms";
In case the reset is successful, the message "reset alarms successful" is shown. In the "Off"
mode, if for some reason the fumes temperature is above 85°C, the stove enters the deactivation
mode.
The message "service" on the display, means that the stove is over 2100 hours of service. The
customer should request for maintenance and only after reset the timer. This alarm does not
influence the normal use of the equipment, is just a warning message.
Code/Alarm
Er01 / High temperature
in pellets tank
Er02 / Fumes
pressostat
Fault in the check up of the sensors and probes during the check-up
process.
When an external dipositive (for example App, or, Chrono) tryes to
deactivate the stove during its operation. The system will only stop until it
reaches the Run Mode stage and the message Ignition Block is shown.
When there is no connection between the motherboard and the display.
Periodic cleaning clycle.
Time and date not correct in case of the stove is disconnected from
power supply for a long period.
Description
110 °C, in both modes,
"On" and "Off".
Combustion chamber
door open,lack of
depression or fumes
extractor malfunction
for 180 seconds, only
visible in "On" mode.
EN // 88
USER'S MANUAL
Cause
Ambient ventilator
doesn´t work; termostat
not working; stove with
insuficient ventilation.
Fume exhaust tube
obstruction or damaged
fumes extractor.
Solution
Call assistance.
Close the door and
reset the alarm.