Er03 / No flames or
insufficient pellets
Er05 / High fumes
temperature
Er07 / Fumes extractor
error
Er08 / Fumes extractor
encoder error
Er12 / Ignition failure
Er15 / Out of power
supply
Er16 / Fail in
comunication with
LCD display
Er39 / Differencial
pressure sensor
damaged
Er41 / Minimum value
/ reference for the
diferencial pressure
sensor not reached in
the checkup stage
Er42 / Maximum value
/ reference for the
diferencial pressure
sensor reached
Fumes temperature
under 55°C (Th03).
Fumes temperature
over 300°C.
No RPM signal; allows
to unlock and work by
tension temporarely
P25=0.
Comunication with
the encoder but the
regulation of the fumes
has failed P25=0.
Max time of 900s and
fumes temperature
below 50°C.
Not connected to power
supply for more than 50
min.
–
The fuel regulation is
interrrupted and the
stove will work with the
standard factory values
and enter "stand by"
mode until the fumes
temperatures drops
bellow <85°C (Th28).
Value of 70 not reached
(FL20). The regulation
is canceled and the
stove enters in shut
down mode.
The regulation is
canceled and the stove
enters in shut down
mode.
EN // 89
USER'S MANUAL
Empty pellet tank;
damaged thermopair;
pellet feeder tube
blocked.
Ambient ventilator not
working or in a low
power level; insuficient
fumes flow; execessive
pellet dosage; fumes
temperature probe
damaged.
Check connection; check if ventilator is
blocked; after correction of this malfunction,
select P25=2 (default value).
Exaust tube or extrator
damaged.
Empty pellet feeder
screw; ignitor damaged;
burner not placed
correctly; fumes
temperature did not
reach 50°C.
Check the electricity tension; check for more
apliances connected at the same time; in case
of out of power supply for a short period of time
(<10s) the stove keeps working normally; if the
system was in "On" mode and the period out of
power supply is between 10s and 50min, the
stove make an ignition after blackout.
Check connection between display and
motherboard.
Check the connection between the
motherboard and the diferencial pressure
sensor; check the reading of the sensor; check
for blockage in the sensor air measure intakes.
Check the connection between the
motherboard and the diferencial pressure
sensor; check for blockage in the sensor air
measure intakes or silicon tubes.
Check the connection between the
motherboard and the diferencial pressure
sensor; check for blockage in the sensor air
measure intakes or silicon tubes.
Refuel the
pellet tank; call
assistance.
Increase the power
level to maximum
(if the problem
persists, call
assistance).
After correction of
this malfunction,
select P25=2
(default value).
Try to start again;
replace the ignitor.
EN