3.3 Secondary information
In the Service menu, select "Informação secundária" (Secondary Information) with P4 and P6
and press P3 to access.
EN
In this menu is the product code, fumes exauhst status, pellet feeder status, ambiente ventilator
and air chaneling status.
Is also possible to check the fumes temperature, ambient temperature, and input status (open=0
closed=1).
3.4 Cleaning reset
In the Service Menu, select "Zerar Limpeza" (Reset Cleaning) with P4 and P6 and access with
P3 key.
In this option is possible to enable or disable this function. To go back to Service Menu press P1.
3.5 Pellet feeder time
In the Service menu, select "Calibração Cóclea" with P4 and P6 and press P3 to access.
In this sub-menu use P4 and P6 to ajust the pellet supply in a range between -7 (-14%) and 7
(+14%). To go back to the Service menu press P1.
3.6 Ventilator calibration
In the Service menu, select "Calibração Ventilador" (Ventilator Calibration) with P4 and P6 and
press P3 to access.
In this sub-menu, use the P4 and P6 keys to ajust the ventilator speed in a range from -7 (-14%)
to 7 (+14). To go back to the Service menu press P1.
3.7 Pellet charge
In the Service menu, select "Carga cóclea" (Pellet charge) with P4 and P6 and press P3 to
access.
This option activates or deactivates the manual pellet charge.
Press P1 to exit the menu.
The last menu is a technical menu for technnical service only and is protected by a password.