Table Of "Burners" Techincal Data; Disposals For Converting And Installing For Other Types Of Gas; Substituting The Nozzle In The Main Burner; Substituting The Nozzle In The Pilot Burner - Lotus cooker F45-78G Guia Para La Intalación E Instrucciones De Uso

Freidoras a gas para uso profesional
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Burner Injector 1/100 mm
Pilot Injector
Consumption
Primary air h=mm

DISPOSALS FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS

Our appliances are tested and regulated with liquid gas /see plate).
The conversion or adaptation to another type of gas must be carried out by a specialized technician. The nozzles for the
various types of gas are supplied in a packet and are marked in hundredths of mm (see table of "burners" technical
data).

SUBSTITUTING THE NOZZLE IN THE MAIN BURNER

In order to operate inside the appliance, it is necessary to empty the water container.
Remove the front fixing screws from the panel, remove the start up cable from the piezoelectric ignition device.
Unscrew the nut and lower the air regulation stirrup.
Using a suitable spanner, unscrew the nozzle and substitute it with the right one (see the "Technical Data" table).
Put the air regulation stirrup into its original position.

SUBSTITUTING THE NOZZLE IN THE PILOT BURNER

The flame of the pilot burner has fixed air.
The only operation necessary is the substitution of the nozzle according to the type of gas.
It is therefore necessary to unscrew the screws as specified in the previous point; with a suitable spanner unscrew the
fitting and substitute the nozzle with a suitable one. With the right nozzle, the flame must lap the thermocouple.

Important!

After having effected the conversion to another type of gas, it is necessary to update the data plate, indicating the type
of gas for which the appliance has been converted.
The appliance contains the instructions necessary for use.
Check the appliances for gas leaks.
Examin the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of
the pilot burner.
Check the lighting and flame of the main burner.
We urge the user to follow the instructions when using the appliance.
With prolonged use of the appliance, it is indispensable to carry out regular maintenance for the safe functioning of the
appliance; we therefore recommend drawing up a contract for after sales service.
Maintenance must be done only by specialized personnel, observing the norms in force and our indications.
It is possible to substitute parts such as the valve, the piezoelectric lighter or gas pipes very simply. To substitute the
parts, proceed as follows:
Valve: after removing the front panel, unscrew the screwed fittings of the gas connections and take out the
thermostat bulb, then substitute the faulty parts, installing the new ones.
To substitute the thermocouple, unscrew the pilot burner fitting, likewise the valve fitting and substitute the
element.
The spark plug must be unscrewed and substituted.
GB

TABLE OF "BURNERS" TECHINCAL DATA

12.68 kWh/KG
G30
BUTANE
28 mbar
8 x 120
30
kg/h 3,470
25

CHECKING FUNCTIONING

MAINTENANCE

SPARE PARTS

IE
12.87 kWh/KG
G31
PROPANE
37 mbar
8 x 120
30
kg/h 3,419
25
33
3
9.45 kWh/m
st.
G20
NATURAL GAS
20 mbar
8 x 180
51
3
m
st./h 4,656
25

Publicidad

Tabla de contenido
loading

Tabla de contenido