Attention!
Before lighting the appliance, it is necessary to wash it with water and washing-up liquid, rinse thoroughly and fill with
oil up to the level marked on the back of the container.
MAIN BURNER IGNITION
Pilot burner ignition
Press and turn the valve knob round to the
position.
Press the piezoelectric button. The flame lights automatically and can be seen through the inspection hole in the front
panel).
The flame could go out in which case repeat the steps.
Main burner ignition and setting the temperature
Turn the valve knob round to the
position.
By turning the graduated thermostat knob from 100°C to 180°C gas flows to the main burner and it ignites.
The green indicator stays alight and indicates mains voltage downstream from the switch, the white indicator indicates
that the main burners are working and will stay alight until the set temperature is reached after which the pilot light
stays on
Turning the main burner off
Turn the graduated thermostat knob round to position "0"; only the pilot burner flame stays alight
Turning the appliance off
Press and turn the valve knob round to position "0". This command stops gas reaching both the main burner and the
pilot burner.
SAFETY THERMOSTAT
The appliance is provided with a safety thermostat which interrupts the gas flow if the temperature of the oil goes above
the maximum set value (230°C). When the safety device intervenes, both the main burner and pilot burner go out.
If this happens, it is possible to restart by pressing down fully the red thermostat button after having removed the
control panel. If the problem occurs again, call in the after sales assistance.
EMPTYING THE CONTAINER
To carry out this operation, it is necessary to open the outlet tap which can only be reached through the cabinet door
situated below. Before doing this, check that the filter and the oil collecting container are in the correct position.
NB: It is advisable not to do this when the oil is too hot.