Operation
Setting the PLAST and AIR temperatures
• Press the Select key (28) to move the cursor to the "PLAST" or "AIR" position
• Set the temperature value with the Up key (29) or the Down key (27)
Monitoring the welding parameters
The setpoint and actual values of the AIR and PLAST temperatures are
constantly monitored. If an actual value deviates from the correspon-
ding setpoint value (value is outside the tolerance range), this is indica-
ted by a status change on the drive status display (30). If necessary,
the drive motor is temporarily blocked. Once the setpoint and actual
values of the AIR and PLAST temperatures are once again within the
tolerance range, "Press any key" appears on the drive status display (30).
You must press any key on the operating unit (32) to release the drive motor
again (restart safeguard). The possible status displays and the tolerance
ranges are shown in the following graphic/table.
No.
Status display
Ready*
1
Release M
2
Heating
3
30s
4
Too hot
5
Press any key
6
26
Status properties
Ready to weld
Deviation of the welding parameters (plastic) > 10 °C
Deviation of the welding parameters (plastic) > –30 °C, drive motor blocked
Start-up delay of 30 sec., drive motor blocked
Deviation of the welding parameters > +30 °C, drive motor blocked
Ready for welding, press any key on the operating unit (32) to release the drive motor