Speci Cations; Details For Ordering - Takex PB-50FA Manual De Instalación

Ocultar thumbs Ver también para PB-50FA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
Troubleshooting
Operation LED does not light
1. Disruption of power or inadequate power.
- Correct power supply.
2. Bad wiring connections or broken wire, short.
- Check and correct wiring.
Receiver Alarm LED does not light when the beam is
broken.
1. Disruption of power or inadequate power.
- Correct power supply.
2. Bad wiring connections or broken wire, short.
- Check and correct wiring.
3. Beam re ection is ooding receiver.
- Remove the re ecting object. Contact TAKEX for
further remedies.
4. Four beams are not broken simultaneously.
- Ensure all beams are broken at the same time.
5. Beam interruption time is shorter than response time.
- Adjust response time.
Receiver Alarm LED stays lit
1. Alignment is out.
- Check and adjust.
2. Obstruction between Transmitter and Receiver.
- Check site / remove any possible obstacles.
3. Optics of units are dirty.
- Clean the optics with a soft cloth.
Intermittent alarm
1. Bad wiring connection.
- Check again.
2. Change of supply voltage.
- Stabilize supply voltage.
3. Obstructing object between Transmitter and Receiver.
- Remove the obstruction.
4. Transient spikes on supply cables.
- Re-locate.
5. Loose installation of Transmitter and Receiver.
- Tighten.
6. Optics of units are dirty.
- Clean the optics with a soft cloth.
7. Poor alignment.
- Check and adjust again.
8. Animals pass through the four beams.
- Change environment or the installation.
Approvals
CE: conform
National approval conditions relating to the use of the
product must be followed.
6

Speci cations

Detection system: Near infrared beam interruption
system
Infrared beam: Double modulation pulsed beam by LED
Protection distance
- PB- 50FA outdoor: 165' ( 50 m)
- PB-100FA outdoor: 330' (100 m)
- PB-200FA outdoor: 660' (200 m)
Max. beam range
- PB- 50FA: 1650' ( 500 m)
- PB-100FA: 3300' (1000 m)
- PB-200FA: 6600' (2000 m)
Response time: 0.05 sec. to 0.7 sec.
Supply voltage: 12 to 30 V DC (non-polarity)
Current consumption
- PB- 50FA: 95 mA
- PB-100FA: 105 mA
- PB-200FA: 120 mA
Alarm output: Dry contact relay: N.C. or N.O.
Reset: Interruption time (Min. 2 sec.)
Contact: 30 V (AC/DC) 1 A
Tamper output: Dry contact: N.C.
Contact operation: Output when cover is
detached
Contact: 30 V (AC/DC) 0.1 A
Alarm LED: Red LED (Receiver) lights when an alarm is
initiated
Attenuation LED: Red LED (Receiver) lights when beam
reception is attenuated
Functions: Double Modulated beam
Tone indicator
Alarm memory indication
Programmed AGC
Auto-Gain Lock function
Monitor Jack
Ambient temperature range: -31ºF to +151ºF
(-35ºC to +66ºC)
Ingress protection: IP55
Mounting position: Outdoor
Wiring: Terminals
Weight
- Transmitter: 42 oz (1.2 kg)
- Receiver: 45.5 oz (1.3 kg)
Appearance: PC resin (wine red)

Details for ordering

PB- 50FA Photoelectric beam sensor ( 50 m)
PB-100FA Photoelectric beam sensor (100 m)
PB-200FA Photoelectric beam sensor (200 m)
BP-200F Pole cover (2 pcs./set)
HTF-24 Heater (2 pcs./set) 24 V DC: 860 mA
Limited warranty
TAKEX products are warranted to be free from defects
in material and workmanship for 12 months from
original date of shipment. Our warranty does not cover
damage or failure caused by Acts of God, abuse,
misuse, abnormal usage, faulty installation, improper
maintenance or any repairs other than those provided
by TAKEX. All implied warranties with respect to TAKEX,
including implied warranties for merchantability and
implied warranties for tness, are limited in duration
to 12 months from original date of shipment. During
the Warranty Period, TAKEX will repair or replace,
at its sole option, free of charge, any defective parts
returned prepaid. Please provide the model number
of the products, original date of shipment and nature
of dif culty being experienced. There will be charges
rendered for product repairs made after our Warranty
Period has expired.

Publicidad