INSTRUCTION MANUAL VOSS.FARMING FENCE SENSOR FS10
7.2
SWITCHING THE DEVICE ON AND OFF
1. To switch on the device, hold the magnet against the magnetic point (3) on the side
of the device for around two seconds.
You will hear an acoustic signal and the LED (1) will light up red.
The LED (1) flashes green and you will hear three acoustic signals.
The device is switched on and the LED (1) lights up green in regular intervals.
Info
Flashing stops after around two minutes to preserve the battery life.
2. To switch off the device, hold the magnet against the magnetic point (3) on the side
of the device for around two seconds.
You will hear an acoustic signal and the LED (1) will light up green.
The LED (1) flashes red and you will hear three acoustic signals.
The device is now switched off.
7.3
PAIRING THE DEVICE WITH THE FENCE MANAGER FM10
The device must be paired with the Fence Manager in order to display the Fence Sensor
data.
Info
► The Fence Sensor can only transmit data to one Fence Manager. It is not
possible to transmit data between different Fence Sensors or to more than
one Fence Manager.
► The Fence Sensor can only be paired with one Fence Manager. Any previous
pairings are immediately cancelled as soon as the device is paired with a new
Fence Manager.
► The Fence Manager can be paired with up to six Fence Sensors.
1. Place the Fence Sensor next to the Fence Manager at a distance of no more than
30 cm.
2. Switch off the Fence Sensor.
3. Hold the magnet against the magnetic point (3) on the side of the Fence Sensor for
more than three seconds.
The LED (1) flashes alternately green and red.
4. Pair the Fence Sensor with the Fence Manager as described in the Fence Manager
FM10 instructions.