Info
Pairing ends automatically after one minute. You can interrupt the process by
holding the magnet against the magnetic point (3).
Once successful pairing is complete, the LED (1) flashes green and you will hear an acoustic
signal.
The Fence Sensor switches off automatically.
Info
The Fence Sensor is not yet connected to the fence and is not measuring voltage,
so it switches off automatically to avoid triggering an alarm via the Fence Manager.
The Fence Sensor is shown in the Fence Manager display with a reading of 0 kV.
The Fence Sensor is now paired and can be mounted at the selected point of the electric
fence.
8
MOUNTING
Make sure that the device is coupled with the Fence Manager FM10 before mounting
it on the fence.
RISK OF ELECTRIC SHOCK
Before performing any work on the electric fence, switch off the energiser battery
and ensure that the fence is not live to prevent injury due to electric shock.
NOTE
► The device is suitable for outdoor use and is able to withstand normal weather
conditions.
► Do not mount the device on the ground or in a damp, wet environment.
► Do not expose the device continuously to water.
Info
Position the device in places where voltage measurement is required (e.g. fence
passage) or in places where problems are more likely to occur (e.g. due to heavy
vegetation).
1. Switch off the energiser battery and the Fence Sensor.
2. Attach the base antenna (6) to the plug connector (2) on the device.
NOTE
Be careful to avoid bending the pin on the antenna when making the connection.
3. Insert the grounding rod into the ground.
4. Connect the grounding cable to the grounding rod and the ground connection (5)
on the device.
26
INSTRUCTION MANUAL VOSS.FARMING FENCE SENSOR FS10
41645 | 11 | 2020 | V1