Installation; Installation Site (Qualified Specialist); Installation Point; There Must Be Ground Drainage - BADU JET Turbo Pro Traducción De Las Instrucciones Para El Manejo Originales

Ocultar thumbs Ver también para JET Turbo Pro:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 262
5

Installation

5.1

Installation site (Qualified specialist)

5.1.1

Installation point

The system is normally installed at the narrow side of the
pool with a recommended minimum pool size of 3.5 x 6 m.
It cannot be installed in a round or oval pool.
5.1.2

There must be ground drainage

Calculate the size of the ground drain according to the
following criteria:
Size of the swimming pool.
Circulation flow rate.
5.1.3

Ventilation and aeration

Ensure sufficient ventilation and aeration. The ventilation and
aeration must ensure the following conditions:
Prevention of condensation.
Minimum distance from motor to the wall: min. 300 mm.
Cooling of the motor and other system components, for
example switch cabinets and control units.
Limitation of the ambient temperature to maximum 40 °C.
5.1.4

Structure-borne and airborne noise transmission

Observe the regulations for constructional noise protection,
for example DIN 4109.
Install the system so that the structure-borne noise and
airborne noise are reduced. Use vibration-absorbing
materials such as blanket insulators for example.
5.1.5

Space requirements

Leave enough space to be able to remove the motor and drive
unit from the rear of the housing.
5.1.6

Fastening elements

Fasten the system parts with screws.
5.1.7

Swimming pool with overflow gutter

Pay attention to adequate dimensioning of the overflow
gutter, piping and splash-water tank when planning the
swimming pool.
08|2020
Installation
EN 17

Publicidad

Tabla de contenido
loading

Tabla de contenido