5.4.11 Dip Switch Settings; Dismantling - BADU JET Turbo Pro Traducción De Las Instrucciones Para El Manejo Originales

Ocultar thumbs Ver también para JET Turbo Pro:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 262
Installation
Error message
*FL* lights up if there is a short circuit in the cable to the LED
floodlight.
*FL* flashes if there is a disruption in the cable to the LED
floodlight.
Note: The error message *FL* only occurs if the condition "LED
light turned on" is met. Normally, without there being an error in
the lighting circuit, this segment can light up briefly due to the
inrush current in the LED lighting module!
*FV* lights up if the voltage in the microprocessor overloads.
Green and orange LEDs on the circuit board
*green LED* lights up: Power supply present in the circuit board
[Volt].
*orange LED* lights up: Motor protection has triggered (over
current).
Check the motor protection settings.
Circuit board fuse
Replaceable fuse: 3.15 A T
The fuse only needs replacing if the green LED [V] is not lit up.

5.4.11 DIP switch settings

Fig. 23
5.5

Dismantling

The system is dismantled in reverse order of the previously
described respective units.
40 EN
08|2020

Publicidad

Tabla de contenido
loading

Tabla de contenido