Volume Regulation - BADU JET Turbo Pro Traducción De Las Instrucciones Para El Manejo Originales

Ocultar thumbs Ver también para JET Turbo Pro:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 262
Commissioning/Decommissioning
6.2.2

Volume regulation

WARNING
Risk of damage to health!
Keep a safe distance from the current nozzle (ball nozzle
(42)).
The volume can be regulated by pressing the upper and lower
piezo buttons (64) installed in the panel (55) or by the remote
control unit (66).
Panel
Arrow up
Arrow down
Remote control
+
-
The system can be controlled over a speed range from 750 rpm to
1650 rpm. The individual power stages are additionally indicated
visually by changing colours on the buttons.
In the boost position (max. volume flow; speed 1650 rpm) the
volume regulation automatically switches back one stage after
15 minutes operating time (safety setting, then off-time).
42 EN
Increase volume flow
Reduce volume flow
Increase volume flow
Reduce volume flow
yellow flashing
yellow
violet
green
blue
red
green
turquoise
blue
blue flashing
1650 rpm
1500 rpm
1350 rpm
1200 rpm
System off
System on
1200 rpm
1050 rpm
900 rpm
750 rpm
08|2020