INSTALLATION
• Conveyor Set-Up
1. Determine primary direction of product
flow. Figure 4A indicates the preferred flow
as related to the drive.
2. Attach supports as show in Figure 4B.
Adjust elevation to required height.
NOTE: If celing hangers are used, see
Ceiling Hangers section.
3. Install electrical controls and wire motor.
•Ceiling Hanger
Installation
If conveyors are to be used in an overhead
application, ceiling hangers may have been
supplied in place of floor supports. Figure
4C shows how a ceiling hanger mounts to
a conveyor section. Ceiling hangers should
be mounted at section joints. For safety
information concerning conveyors mounted
overhead, refer to "Installation Safety Precautions" on Page 3.
FIGURE 4B
• NBEZ Set-Up
1. Mark a chalk line on the floor to locate the center of the conveyor.
2. Place the drive section in position.
3. Place remaining sections on the extended support of the
previous section (Figure 4B and4C).
4. Insure that each bed section is square prior to setting in
place. Refer to Figure 4A. Page 5 for Instructions on How To
Square the Beds. Bed sections must be square in order for the
belt to track properly.
5. Fasten sections together with butt couplings and pivot plates
(Figure 4B and 4C). Hand tighten bolts only at this time.
6. Pull a string taut about 1-2 inches over the top of rollers from
the center of infeed end to center of discharge end of conveyor
to establish a straight line for the conveyor. Measure from string
to every bed joint and adjust as necessary to set the entire
length of conveyor is straight to the string. Use a laser beam
over the entire length to adjust each support to level conveyor.
7. Tighten all butt coupling and support mounting bolts and lag
conveyor to floor.
8. Connect the EZLogic® zone controller cordsets at the sections joints.
9. Mount the IOP (for the EZLogic® System) to the conveyor, near the center. Connect the IOP to the EZLogic® System. See page 7 for more information about these
connections.
FIGURE 4E
FIGURE 4A
NOTE: See the EZLogic® GEN3 Component Manual for more information about the IOP power
connections and for more information about EZLogic® components.
4
FIGURE 4C
FIGURE 4F
FIGURE 4D