INSTALLATION continued
8. Connecting the Storage Tank to the System
CAUTION
When tank is full, it weighs approximately
29 kg. Provide ample support under the tank.
A. To prevent leaks, apply 3 or more wraps of Teflon tape
to threads on tank. Thread the tank valve onto the top
of the tank opening. Turn tank so handle is in line with
tubing.
CAUTION
The tank/valve connection will leak if not
properly sealed. Teflon tape will normally seal
the threaded connection.
B. Locate the 1/4-inch tubing. Place a mark on the tubing
5/8-inch from each end. Moisten one end of the tubing
with water and insert with a twisting motion into the port
of the tank valve until the 5/8-inch mark is flush with
the quick connect fitting. Then locate the tank near the
system's installation area.
1/4" Tube
5/8"
B
Figure 13
C. Cut the tubing to correct length. Install free end of tubing
into white quick-connect fitting on the post filter tee on
the right side. Do not cut tubing again.
D. Place entire system over mounting screws on wall and
slide down.
Make certain system is firmly attached to wall
CAUTION
to prevent it from falling and possibly becoming
damaged.
NOTE: Use caution not to bend or pinch the tubing behind
the system while attaching to mounting screws.
9. Connecting the Supply Adapter and Inlet Filter
A. Locate remaining length of 1/4-inch plastic tubing.
B. Push into quick connect fitting on the right side of
system.
C. Cut the tube to a length that will allow connection to the
cold water supply fitting. Ensure the tubing does not
kink. Push the tube into the fitting.
1/4" Tube
Figure 14
A
Apply
Teflon
tape
5/8"
A
16 mm
C
5/8"
16 mm
10. Installing the Membrane
A. Remove tube attached to membrane housing by
pressing in the white collar around the fitting while
pulling the tubing with your other hand.
B. Hold the membrane housing with one hand and
unscrew the cap (wrench provided) with other hand
to remove. To make it easier to hold the membrane
housing, you may want to remove the postfilter.
C. With clean hands (sanitary gloves preferred), remove
the membrane from the plastic bag. HANDLE WITH
CARE.
Do not unwrap the tape around the membrane,
CAUTION
as it is part of the membrane. Do not squeeze
membrane.
D. With the double O-ring side first, push membrane into
housing until it stops.
About 1/8-inch of the membrane's plastic core will stick
out beyond the housing.
Figure 15
E. Use clean silicone grease (pack is included with the
system) to lubricate both O-rings and the brine seal.
Hand-tighten membrane housing cap until you feel
resistance, then tighten an additional 1/2 turn. Do not
over-tighten.
F. Reinsert the tube by pushing it into the quick connect
fitting.
11. Faucet Operation
For controlled water flow, rotate the handle to the right
(clockwise).
Model RO-2600 5 StageReverse Osmosis System SE11 • 7