High Altitude Operation; Remote Start - Westinghouse iGen7500 Manual De Usuario

Generador portátil de combustible dual
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
3. Remove the nut securing the neutral ground wire and
attach the bonded jumper wire. Reinstall the nut.
4. Reinstall the alternator cover.
IMPORTANT: Apply a new "NEUTRAL UNBONDED"
Label over the "NEUTRAL BONDED TO
FRAME" label on the front of the control
panel.

HIGH ALTITUDE OPERATION

Engine power is reduced the higher you operate above sea
level. Output will be reduced approximately 3.5% for every
1000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at
altitudes over 5,000 ft. (1524 m). Operation without this
adjustment will cause decreased performance, increased
fuel
consumption,
DO NOT operate the generator at altitudes below 2,000
ft. (762 m) with the high altitude kit installed. Engine
damage may occur.
High Altitude Carburetor Kit Part# 518063

REMOTE START

Verify that the area around the generator is clear before
remote starting the generator.
The remote start key fob included with the generator should
be attached to the recoil handle or control panel. If your
unit was shipped without a key fob, contact Westinghouse
customer service.
The generator can be started remotely from up to 99 feet
(30 meter) using the remote start key fob.
Note: As the batteries in the remote start key fob drain,
operational distance will decrease.
Neutral ground wire
Bonded jumper wire
and
increased
NOTICE
WARNING
PAIRING THE REMOTE START
Remote replacement batteries: (2) CR2016
If the remote start key fob is replaced or needs re-paired to
the generator, follow this procedure.
1. Turn the generator battery switch to the ON position.
The power indicator light will illuminate.
Push button START/STOP
2. Push and hold the red Pairing button on the side of the
control panel until the START/STOP button illuminates.
3. Push and hold the STOP button on the key fob until the
START/STOP button illumination turns OFF. Release
the button. The START/STOP button will illuminate after
emissions.
the button is released.
4. Push and hold the START button on the key fob until the
START/STOP button illumination turns OFF. Release
the button. The START/STOP button will illuminate after
the button is released.
5. Push the Pairing button on the side of the control panel
until the START/STOP button illumination turns OFF.
Release the button.
6. Turn the generator battery switch to the OFF position.
The remote is now paired.
Westinghouse Outdoor Power Equipment, LLC | 15
Power indicator
Pairing button
Key Fob
Activation Light
START
START Button
STOP
STOP Button
Battery switch

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Wgen7500

Tabla de contenido