Aventics AV03 Serie Instrucciones De Servicio página 8

Ocultar thumbs Ver también para AV03 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
AVENTICS | AV03/AV05 | R412026229–BAL–001–AA | English
Exchanging components
Danger of explosion! Do not release plugs or
valves when the VS is under voltage.
Before you release the plug or replace valves you must
disconnect the valve system from the supply voltage
and ensure that there is no explosive atmosphere.
Make sure that all components and seals are mounted
correctly before recommissioning the system.
Conversion of the Valve System
Conversion of the valve system for use in explosive
atmospheres is permissible exclusively within the
scope described in the documents listed in section
"Required and supplementary documentation".
Generally verify in the AVENTICS online configurator,
whether the new configuration complies with the
ATEX requirements. Document this verification
before commissioning the device.
The warranty of AVENTICS only applies to the delivered
configuration. The warranty will not apply after a
conversion that cannot be presented in the AVENTICS
online configurator.
7
ATEX identification
AVENTICS
30880 LAATZEN - GERMANY
AV03 and/or AV05
INERIS 15ATEX3001U
(Serial number)
(Year of construction)
II 3 G
Ex nA IIC Gc
WARNINGS:
- DO NOT SEPARATE WHEN ENERGIZED.
The AV valve system is certified as a component according
to the EU directive 2014/34/EU. Final certification
including the temperature index for the cover housing
must be carried out by the system constructor in
conjunction with the system certification.
Valve systems of the series AV03/AV05 with ATEX
identification comply with the requirements of the
EU-directive 2014/34/EU. Characteristics and
applications that are derived from the ATEX ID are
explained in the following:
Device class: All areas, except for mining
II
Device category: Suitable for use in zone 2
3G
Design sample certification
INERIS 15
ATEX3001
U
EX component –see the operating
instructions for additional requirement
Ignition protection type: No danger of
nA
ignition with normal operation
Sub-group C
IIC
see equipment category
Gc EPL
Warning signs on device
Observe the following warning signs on the device:
WARNING
Do not separate when energized
Identification on the name plate
1
2
3
4
5
1 Warning: Do not
disconnect when
energized
2 ATEX symbol
3 Mat. no.
4 Serial number
5 Registered trademark of
AVENTICS GmbH and
address
9
8
7
6
00132734
6 Series designation
7 QR code
8 Date of manufacture:
[Year]W[week]
9 ATEX identification
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Av05 serie

Tabla de contenido