Wacker Neuson WM 80 Manual De Reparaciones página 147

Tabla de contenido

Publicidad

Threadlockers and Sealants
Threadlockers and Sealants (continued)
TYPE
( ) = Europe
Loctite 496
Hernon 110
Omnifit Sicomet 7000
Loctite Primer T
Hernon Primer 10
Omnifit VC Activator
Threadlocking adhesives and sealants are specified throughout this
manual by a notation of "S" plus a number (S#) and should be used
where indicated. Threadlocking compounds normally break down at
temperatures above 175°C (350°F). If a screw or bolt is hard to
remove, heat it using a small propane torch to break down the sealant.
When applying sealants, follow instructions on container. The sealants
listed are recommended for use on Wacker Neuson equipment.
COLOR USAGE
Clear
Instant adhesive for bonding rubber,
metal and plastics; general purpose.
For gaps up to 0.15 mm (0.006")
Read caution instructions before using.
Temp. range: -54 to 82°C (-65 to 180°F)
Aerosol
Fast curing primer for threadlocking,
Spray
retaining and sealing compounds. Must
be used with stainless steel hardware.
Recommended for use with gasket
sealants.
PART NO. –
SIZE
52676 - 1oz.
2006124-6 oz.