Kohler K-2972 Guia De Instalacion página 14

Válvula de mezcla termostática
Ocultar thumbs Ver también para K-2972:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Seal
Reverse the Inlet Supplies
The inlet connections are indicated on the inlet ports of the
thermostatic valve assembly. Left is HOT and right is COLD. If this
configuration is not suitable for your installation, the cartridge may
be rotated 180° to reverse the hot and cold inlet ports.
NOTE: Refer to the Homeowners Guide for integral supply stop
operation.
NOTE: DO NOT pull the removal clip from the cartridge assembly
at any time during this procedure. The retaining clip helps hold the
temperature limit stop and detent components in place and reduces
or eliminates the need for temperature adjustments.
With the valve already installed and pressurized:
Turn both integral supply stops 90° counterclockwise until they
contact the stop bracket.
Turn the volume control valve stem (not shown) fully clockwise
to release the pressure.
Slowly loosen the head nut, turning it counterclockwise. This will
begin to draw the cartridge out of the valve body.
1145568-2-B
Remove the cartridge and rotate 180˚.
Supply Stops
Seal
Tab
Head Nut
14
Cartridge
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-2975K-2973K-2976

Tabla de contenido