Installation Example - Gree GRS-CQ8.0Pd/NaE-K Manual De Usuario

Bomba de calor aire-agua split versati
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SPLIT
TYPE

4. Installation Example

CASE 1: Connecting Under floor Coil and Fan Coil Unit
Outdoor
Notes
(a) The two-way valve is very important to prevent dew condensation on the floor and FCU while cooling mode;
(b) Type of thermostat and specification should be complied with installation of this manual;
(c) The bypass valve must be installed to secure enough water flow rate, and should be installed at the
collector.
(d) When the FCU and the underfloor coil are used at the same time, performance of the underfloor coil is
satisfied firstly. When performance of the FCU is required, then "Floor config" should be set to "Without".
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
Indoor
11
Air-to-water Heat Pump Split Versati

Publicidad

Tabla de contenido
loading

Tabla de contenido