12
WATER SUPPLY CONNECTION
WARNING
To avoid electric shock, which can
cause death or severe personal injury,
disconnect the unit from electrical pow-
er source before connecting a water
supply line to the appliance.
CAUTION
To Avoid Property Damage:
• Use Copper or Stainless Steel braid-
ed tubing for the water supply line.
Frigidaire does not recommend wa-
ter supply tubing made of ¼" plastic.
Plastic tubing greatly increases the
potential for water leaks, and the
manufacturer will not be responsible
for any damage if plastic tubing is
used for the supply line.
• DO NOT install water supply tubing
in areas where temperatures fall
below freezing.
• Chemicals from a malfunctioning
softener can damage the ice maker.
If the ice maker is connected to soft
water, ensure that the softener is
maintained and working properly.
IMPORTANT
Ensure that your water supply line connec-
tions comply with all local plumbing codes.
Before Installing The Water Supply Line,
You Will Need:
•
Basic Tools: adjustable wrench,
flat-blade screwdriver, and Phillips
screwdriver
•
Access to a household cold water
line with water pressure between 30
and 100 psi.
•
A water supply line made of ¼" (6.4
mm) OD, copper or stainless steel
tubing. To determine the length of
tubing needed, measure the distance
from the ice maker inlet valve at the
back of the refrigerator to your cold
water pipe. Then add approximately
7� (2.1 m), so the refrigerator can be
moved out for cleaning.
•
A shutoff valve to connect the water
supply line to your household water
system. DO NOT use a self-piercing
type shutoff valve.
•
Do not reuse compression fitting or
use thread seal tape.
•
A compression nut and ferrule
(sleeve) for connecting a copper
water supply line to the ice maker
inlet valve.
NOTE
Check with your local building author-
ity for recommendations on water
lines and associated materials prior to
installing your new refrigerator. Depend-
ing on your local/state building codes,
Frigidaire recommends for homes with
existing valves its Smart Choice
line kit 5304490728 (with a 6�Stainless
Steel Water Line) and for homes without
an existing valve, Frigidaire recom-
mends its Smart Choice
5304490717 (with a 20�copper water
line with self-tapping saddle valve).
Please refer to www.frigidaire.com for
more information.
To Connect Water Supply Line To Ice
Maker Inlet Valve
1.
Disconnect the refrigerator from
electrical power source.
2. Place the end of the water supply
line into a sink or bucket. Turn ON
the water supply and flush the supply
line until the water is clear. Turn OFF
the water supply at the shutoff valve.
3. Remove the plastic cap from the wa-
TM
ter valve inlet and discard the cap.
4. If you use copper tubing - Slide the
brass compression nut, and then
the ferrule (sleeve) onto the water
supply line. Push the water supply
line into the water valve inlet as far
as it will go (¼"/6.4 mm). Slide the
ferrule (sleeve) into the valve inlet
and finger tighten the compression
nut onto the valve. Tighten another
half turn with a wrench; DO NOT
overtighten. See Figure 1.
water
®
water line kit
®