Alarm List, Problem And Possible Solutions - BOREAL RADIOFRECUENCIA Serie Instrucciones De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

11.12

ALARM LIST, PROBLEM AND POSSIBLE SOLUTIONS

ALARM
DESCRIPTION
CODE
AL1
BLACK OUT
AL 2
SMOKE PROBE
AL 3
TEMP. SMOKE
AL 4
BREAKDOWN EXTRACTOR
AL 5
START-UP FAILURE
AL 6
NO PELLET
AL 7
THERMAL ALARM
AL 8
DEPRESSION
AL 9
LACK OF FLOW
AL
FLOWMETER FAILURE
AL b
ENDLESS ERROR
PROBLEM
The stove or insert has been
temporarily without electric current.
Problem with the smoke probe.
The smoke temperature is higher
than 270ºC.
Problem with the smoke extractor.
The fuel does not fall or burn.
There is no fuel in the hopper or it
does not fall inside the burner.
The fuel thermal security thermostat
has shot up.
The combustion chamber is on
depression.
Lack of primary air or installation
not appropriate.
The flow sensor is broken.
The endless spins continuously.
POSSIBLE SOLUTION
Press button 3 for a few seconds and let the final cleaning stage to
finish. The boiler will come back to the turn-off status.
Check the probe connection or replace it.
Regulate the pellet drop and/or the extractor speed. Verify the type
of fuel that has been used.
Check the extractor electrical connection or replace it.
Check the geared motor and the resistor way of working. Check a
possible blockage of the endless. Verify that there is fuel in the tank.
Refill tank. Check the endless working. Check the fuel
characteristics and that it has not become compacted. Clean the
bottom of the hopper.
Restart the thermostat manually. Check the reason why the
temperature is excessive and provoked the overheating (fuel drop,
draw excess, fuel type...)
Verify that the chamber is hermetic : check locks, gaskets... etc.
Check that the gas installation is correct (excess of horizontal
sections, elbow joint, etc). Possible fuel blockage.
Check the primary air inlet. Verify installation (excess of horizontal
section, curves, dirtiness, etc).
Replace the flow sensor.
Verify the electrical connection of the endless.
EN
47

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Slim 9Slim 12Insert 7

Tabla de contenido