11.5
IGNITION FAILURE ALARM
In case of ignition failure (after 20 minutes at least) the control will show up an alarm as follows.
EN
To deactivate the alarm press button 3 and the stove will come to the normal state after doing the final cleaning.
ALARM 6
NO PELLET
MENU
11.7
THERMAL ALARM
If in working phase the thermal security alarm is shows up, the turn-off stage will be immediately activated. This alarm means
an overheating of the internal part of the tank, this device blocks the operation of the machine. The restart needs to be done
manually by an authorised technician.
The restoration of the 90ºC safety device is not included in the warranty unless the technical
assistance centre demonstrates a faulty component.
ALARM 8
FAILURE
PRESSURE
MENU
11.9
LACK OF PRIMARY AIR INTAKE FLOW ALARM
Your stove has a flow sensor placed inside the primary air suction pipe. It detects the proper circulation of combustion air and
the smoke exhaust. In case of insufficient air inlet (due to incorrect smoke outlet or improper air intake), the sensor sends a
"block" signal. After that the turn-off stage will be immediately activated.
ALARM b
ENDLESS
ERROR
MENU
11.11
FLOW SENSOR ANOMALY SENSOR
In case of anomaly of the flow sensor, placed on the primary air aspiration tube, a blockage signal is send to the stove or
insert and right after the turn-off stage will be immediately activated.
If this alarm appears you must contact the technical support service.
46
11.6
SWITCHING-OFF FAILURE DURING WORKING PHASE
If the flame extinguishes during the working stage and the smoke temperature goes lower than the minimum working
threshold, the alarm does go off and the turn-off stage will be immediately activated.
To deactivate the alarm press button 3 and the stove will come to the normal state after doing the final cleaning.
11.8
COMBUSTION CHAMBER PRESSURE ALARM
It happens when there is a pressure change in the combustion chamber (door open, dirt registers, air returns...). The
electronic pressure switch blocks the working of the stove and shows the alarm. After that the turn-off stage will be
immediately activated.
11.10
WORM GEAR FAILURE ALARM
The control of the fuel amount to the stove is automatically made through the electronic programming. It goes off in the event
of the endless breakdown. If this happens, the stove stops and the display will show up the following alarm. Right after, the
turn-off stage will be immediately activated.
If this alarm appears you must contact the technical support service.
ALARM 5
FAILURE
IGNITION
MENU
ALARM 7
SECURITY
THERMAL
MENU
ALARM 9
FLOW
ALARM
MENU
ALARM
FAILURE
FLOWMETER
MENU