6556042.book Seite 43 Freitag, 15. April 2016 3:13 15
Operating Instructions BA ULTIMATE POWER+
8 Maintenance
8.2
Replacing the bulb in the handpiece
For turbines with W&H or Bien-Air connection, the bulb is located in the
Attachment _ W&H and BienAir
turbine handpiece.
Highspeed handpiece with W&H connection:
Highspeed handpiece_ neutral
CAUTION! The bulb may be hot. This may cause burns! Allow the
W&H T1 turbine
bulb to cool down.
1. Detach the turbine from the quick coupling.
2. Unscrew end sleeve (B) with the tool (C) supplied and detach it.
3. Detach the coupling fitting (A).
C
A
B
43