Connection And Operation - Migatronic CMI Serie Guía De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 91

Connection and operation

Warning
Read warning notice and
instruction manual carefully
prior to initial operation and
save the information for later
use.
Unpacking the CMI 273i/223i TWIN
After unpacking and prior to use, proceed as follows (see
drawing):
Please note:
CMI 183i/223i has a permanently fixed trolley.
Permissible installation
Mains connection
Connect the machine to the correct mains supply. Please
read the type plate (U
) on the rear side of the machine.
1
yellow/green
brown
black
grey
yellow/green
brown
black
grey
1
2
0
l
3x200-440V
L1
L2
L3
N
1x200-440V
L
N
3
Important!
In order to avoid destruction of
plugs and cables, good electric
contact is required when connect-
ing earth cables and welding hoses
to the machine.
Connection of welding hose
Torch adjustment (Dialog torch)
The welding current, wire feed speed or thickness of
material can be adjusted both from the machine and the
welding torch if a welding hose with dialog torch is in use.
The torch adjustment is passive without Dialog torch.
Lifting instructions
Lifting hooks can be used at the sack barrow for lifting
with a crane (figure 1).
The trolley with four wheels cannot be lifted with a crane
but only manually using the handle (figure 2).
The machine must not be lifted with a mounted gas
cylinder!
Fig. 1
Fig. 2
Do not lift the machine by
the handle.
Do not step on the handle.
12

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cmi 183iCmi 223iCmi 223i twinCmi 273iCmi 273i twinCmi boost 273i/273i twin

Tabla de contenido