Thermor ONIX CONNECT Instrucciones De Instalacion Y De Uso página 6

Ocultar thumbs Ver también para ONIX CONNECT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
EN
Installation manual: General installation diagram
2. How to install your water heater
2.1 Vertical wall-mounted water heater:
Flat and Square units
Position the drilling template (printed on the packaging)
on the wall surface and mark the points corresponding to
the water heater model, ensuring the minimum clearance
spaces to be left around the water heater are respected
(see diagram A).
Drill and plug the water heater, using attachments which
are 10 mm in diameter (Ø) suitable for your wall type
(drywall, concrete, brick).
Important: your wall must be able to bear the weight
of the water heater when fi lled.
Securely attach the brackets (for 25/40/65/80 L capacities) or
the single bracket (for 75/100/150 L capacities), and use a rule
to check the distances between the brackets. The elements
used for mounting must not protrude beyond the contact
surface with the water heater.
PLEASE NOTE: For models 25/40/65/80 L, if the wall is suffi ciently
sturdy, it is possible to use a single bracket for mounting.
To ensure it is secure, position the lower bracket in the
corresponding mountings on the water heater, with the
openings facing down. The lower bracket acts as a stop,
resting on the wall without screws (Diagram C or D).
Lift and fi t your water heater against the bracket(s), taking care to position the mountings on
top of the brackets.
Lower the water heater until the mountings engage in the notches.
Once the mountings are engaged, it will no longer be possible to slide the water heater from side to side
without exerting signifi cant force.
Diagram A
CEILING
È
400 mm
FLOOR
The hot water outlet must be positioned
4
to the left of the water heater.
Diagram B
20 mm
min.
Bracket
Water heater
Bracket
Water heater
Diagram C
Contact
on
area
Indicative weight
of the filled
water heater
Range
Capacity
25 L
40 L
Flat
65 L
80 L
75 L
Square
100 L
150 L
Wall
YES
Wall
NO
Diagram D
Contact
on
area
on
Mass
45 kg
70 kg
100 kg
120 kg
105 kg
135 kg
200 kg
on
on

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Square ceramics connect

Tabla de contenido