3
Straight
Hose!
No kinks!
KEEP THE HOSES AS STRAIGHT
AS POSSIBLE
To reduce friction, do not coil or kink the
hoses. When pumping from a well or stream,
raise the inlet hose a few inches off the bot-
tom to avoid sucking in sand, silt or pebbles
(which can disable the impeller). Install the
suction attachment (included) to protect the
pump from large solids.
NOTICE: Attach the suction attachment to the
end of the inlet line and place it in at least
1/2" of water at the lowest point to be
pumped. Be sure all connections are air tight.
WA782
4
NOTE: If you don't get water in
30 seconds or less, add more oil
and repeat the process.
See Step 1.
No Coils!
INLET HOSE GOES IN THE WATER;
OUTLET HOSE STAYS OUT OF THE
WATER. MOTOR MUST STAY DRY
Make sure all inlet connections are tight (no
air leaks) and the inlet hose is in the water.
Make sure the end of the outlet hose is not
under water. If the outlet is under water, the
pump may not work.
R106: Plug the cord into a 3-wire, 115 volt,
60 Hz, grounded A.C. outlet.
R107: Connect the RED battery clip to the
positive terminal of a 12 volt battery and
connect the BLACK clip to the negative
terminal of the battery. Keep the battery clip
wires away from moving parts or hot spots of
an engine.
You should get water in 30 seconds or less. If
not, add more oil and repeat the process. If
your pump does not prime on the second try,
check the impeller and the inside of the
pump head for wear. Replace as needed.
In rare cases you may need to prime the
pump. To prime it, fill the suction hose with
water, put it back in the water source, and
start the pump.
The motor must have air circulation around it
for proper cooling. This pump will lift water
12'; trying to lift water more than 12' can
cause the motor to run hot. The motor has a
thermal overload which will stop it if it gets
too hot. If the motor stops, allow it to cool
for 30 minutes before trying to start it again.
4
Plug in pump to start it.
Outlet Hose
Water OUT
Water IN