PREVENTATIVE MAINTENANCE
Monthly
• Blow off all dust and debris from the system.
• Check for any unusual wear on components.
• Check for any unusual wear or buildup on the side
of the seal assembly.
REPLACING THE EDGE SEAL
Materials required:
• H-4008-SEALR
NOTE: The system must be ON for the following
procedure. Ensure components are cool
before proceeding.
1.
Lower the clamp handle to open the edge seal.
PAGE 7 OF 30
MAINTENANCE AND REPAIR
Edge Sealer
Figure 8
Clamp
(Shown Open)
Figure 10
Receptacle
Holes (3)
2. Push the release button (in the center of the edge
seal wheel) in while pulling the edge seal wheel and
black plastic gear straight out approximately .25"
(6mm). (See Figures 8 and 9)
3. Pull the edge seal wheel away from the black
plastic gear. (See Figure 10)
4. Install the new edge seal:
• Align the three (3) connection pins on the new wheel
with the three (3) receptacle holes in the seat.
• Push the release button in while pushing the wheel
fully against the black plastic gear.
• Do not load film. Raise the clamp handle to close
the edge seal.
5. Load film, press (//) reset key, then start key to
calibrate the new edge seal – 3' (1m) of uninflated
material will automatically feed out.
Figure 9
Release
Button
Black Plastic
Gear
Edge Seal
Edge Seal
Wheel
Edge Seal
Wheel
0115 IH-4008