Palabra
Nombre de variable
de datos
...
01<=Invnn<=30
710.0
AssignWeatherIInvnn
770.0
ConstPerfWs1
774.0
ConstPerfWs2
778.0
ConstPerfWs3
782.0
ConstPerfWs4
786.0
ConstPerfWs5
790.0
ConstPerfWs6
794.0
ConstPerfWs7
798.0
ConstPerfWs8
802.0
WinCC_exist
802.1
P_Cont_Mode
802.2
P_Cont_FltMode
804.0
P_Cont_TimeInvOrder
808.0
P_Cont_Threshold_LL
812.0
P_Cont_Threshold_HL
816.0
P_Cont_Max_Time
820.0
P_Cont_Min_Time
824.0
P_Cont_Hysteresis
828.0
P_Cont_InvSpare
830.0
P_Cont_DeadBand
834.0
CosPhi_Cont_DeadBand
838.0
Q_Cont_Auto
840.0
Q_Cont_U_Hys
844.0
Q_Cont_U1Ind
848.0
Q_Cont_U2Ind
852.0

Q_Cont_U_Ind_h

856.0
Q_Cont_Q_Max_Ind
PVS ControlBox 300
Instrucciones de servicio, 01/2013, A5E03642530A/003
8.5 La interfaz de parámetros de la regulación del parque
Tipo de
Denominación
datos
Assignment Inverter to
weatherstation
INT
Assignment Inverter nn to
weatherstation [1..8]
REAL
constant Wp for performance
ratio weatherstation 1
REAL
constant Wp for performance
ratio weatherstation 2
REAL
constant Wp for performance
ratio weatherstation 3
REAL
constant Wp for performance
ratio weatherstation 4
REAL
constant Wp for performance
ratio weatherstation 5
REAL
constant Wp for performance
ratio weatherstation 6
REAL
constant Wp for performance
ratio weatherstation 7
REAL
constant Wp for performance
ratio weatherstation 8
BOOL
WinCC exists in plant
BOOL
Controller Mode
BOOL
Controller Fault Mode
TOD
Controller Time to set Inverter
Order
REAL
Controller Threshold Minimum 0.0
REAL
Controller Threshold
Maximum
REAL
Controller Timer Inverter
Maximize
REAL
Controller Timer Inverter
Minimize
REAL
Controller Hysteresis
INT
Controller Inverter Spare
REAL
Deadband active power PI
controller
REAL
Deadband cos(Phi) PI
controller
BOOL
Q controller automatic switch
REAL
Hystersis U
REAL
Linear slope : U
REAL
Linear slope : U
REAL
U:prot: Shutdown level
REAL
Max. sustainable ind. reactive
power
Preasign
ación
1
2000.0
2000.0
2000.0
2000.0
2000.0
2000.0
2000.0
2000.0
0
0
1
TOD#0:0
:0:0
100.0
2.0
2.0
1.0
1
0.1
0.001
false
0.1
at Q
=0
21.4
1
1
at Q=Q
21.65
2
max
21.8
0.0
Software
Acceso
Campo
obligatorio
Read / write
r/w
No
r/w
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No
r/w
No