MAIN AREAS OF APPLICATION
2
MAIN AREAS OF APPLICATION
2.1
APPLICATION
The main area of application are thick layers of highly viscous
coating material for large areas and a high consumption of
material.
Priming and final coating of large areas, sealing, impregnation,
construction sanitation, façade protection and renovation, rust
protection and building protection, roof coating, roof sealing,
concrete sanitation, as well as heavy corrosion protection.
EXAMPLES OF OBJECTS TO BE SPRAYED
Large-scale construction sites, cooling towers, bridges, sewage
treatment plants and terraces.
DO NOT use this equipment to spray water or
acid.
Do not lift by cart handle when loading or
unloading.
Device is very heavy. Three-person lift is required.
Attention
FLUID PUMP
The HYDRA X fluid pump is mounted to a lift mechanism that
can be automatically raised or lowered based on the container
from which material is being drawn.
The inlet filter (rock catcher) on the bottom of
i
the suction tube will need to be removed when
drawing material from a sealed drum.
8
2.2
COATING MATERIALS
PROCESSIBLE COATING MATERIALS
Diluting lacquers and paints or those containing solvents, two-
component coating materials, dispersion and latex paints.
No other materials should be used for spraying without Titan's
approval.
Pay attention to the Airless quality of the coating
i
materials to be processed.
VISCOSITY
The unit is able to process coating materials with up to
65,000 mPas. If highly viscous coating materials cannot be taken
in or the performance of the unit is too low, the paint must be
diluted in accordance with the manufacturer's instructions.
Attention: Make sure, when stirring up with
i
motor-driven agitators that no air bubbles are
stirred in. Air bubbles disturb when spraying and
can, in fact, lead to interruption of operation.
COATING MATERIALS WITH ABRASIVE MATERIALS
These particles have a strong wear and tear effect on valves and
tips, but also on the spray gun. This impairs the durability of
these wearing parts considerably.
TWO-COMPONENT COATING MATERIAL
The appropriate processing time must be adhered to exactly.
Within this time rinse through and clean the unit meticulously
with the appropriate cleaning agents.
FILTERING
This unit is not equipped with a high-pressure outlet filter.
However, a high pressure outlet flter kit can be purchased
separately if desired.
All compatible accessories for this unit are listed in the online
service manual, Form No. 2412594, available for download at
www.titantool.com.