Outdoor Unit Installation; Installation - Electrolux EXM18HV1W Manual De Instalación

Ocultar thumbs Ver también para EXM18HV1W:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Outdoor Unit installation

step 1: securing of Outdoor Unit
• Anchor the outdoor unit by fixing the 4 holes
existent in its based with 4 bolts and nuts of
10 mm tightly (not included).
Place the outdoor unit over a horizontal
concrete or rigid surface (never directly over
grass or land).
Air inlet
caution
• If a suspended installation is needed,
the installation bracket must allow the
fix according to dimensions on the
figure above.
• The wall where the unit will be installed
must be of solid brick, concrete or
provided with other reinforcement ways
to fix the bracket. The fixation of the
bracket to the wall and the bracket to
the air conditioner must be firm, steady
and leveled.

installation

step 1: installation of Mounting Plate
1 Fit the mounting plate horizontally on the wall
with five or more self-tapping screws (type
ST4x25, item 3 on page 3).
2 be sure that the mounting plate has been
fixed firmly enough to withstand about 60kg.
Meanwhile, the weight should be evenly shared
by every screw.
3 3 If the wall is made of brick, concrete or the
like, drill five (5) or more holes of 5mm diameter
in the wall. Insert clip anchor (item 2 on page 3)
for appropriate mounting screws.
4 The water tray's outlet for the indoor unit is two-
way drainage design. During installation, the
indoor unit should slightly slant to water tray's
8
Air inlet
Air outlet
step 2: Outdoor Condensate Drainage
(only for heat pump model)
• During heating operation, the condensate and
defrosting water should be drained out reliably
through the drain hose.
• Install the outdoor drain connector in the drain-
water hole on the chassis of outdoor unit, and
attach the drain hose to the connector so that
the waste water formed in the outdoor unit can
be drained out.
• The drain-water hole must be plugged.
Whether to plug other holes will be determined
by the installer according to actual conditions.
• In case of a drain hose, the unit must be
installed on a base more than 3cm height.
Hose of inner dia. 16mm
(not provided)
outlet for smooth drainage of condenser water.
Fit the mounting plate and drill holes in the wall
according to the wall structure and correcponding
mounting points on the mounting plate.
(dimensions are in mm unless otherwise stated)
Cool Capacity (W/h)
EXM09HV1WI
EXM12HV1WI
Drain-water
hole
Chassis
Drain
connecter
Mounting Plate type
A
b

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Exm24hv1w

Tabla de contenido