B. in cases where the outdoor unit is
installed below the indoor unit level:
• Wrap the piping, drain hose and connecting
cable from the down to up.
• Secure the wrapped piping along the exterior
wall using saddle or equivalent.
Seal small openings
around piping with a
gum type sealer.
Trap is required to prevent water
from entering into electrical parts.
C. in cases where the outdoor unit is
installed above the indoor unit level:
• Wrap the piping and connecting cable from
the down to up.
• Form a trap to prevent water from entering
the room.
• Secure the wrapped piping along the exterior
wall using saddle or equivalent.
Seal small openings
around piping with a
gum type sealer
Wrapping
Pipe
Drain hose
Connection
cable
Drain hose
Trap
Trap
Drain hose
step 9: Electrical installation
safety Precautions
Electrical safety rules before starting the
installation:
1 A dedicated power supply circuit and breaker
should be provided
for the products which
are not supplied with a
service cord and plug
in accordance with
local electrical safety
regulations.
2 The circuit breaker must have the functions of
magnetic tripping and heat tripping to prevent
short circuit and overload.
3 The appliance shall be installed in accordance
with national wiring regulations.
4 A circuit breaker with proper capacity must be
installed according to the table below.
Cooling
Capacity
(w)
2600
3500
5000
7000
5 In case of problems in power supply, the air
conditioner must not be installed before the
customer fixes the problem.
6 be sure the power supply matches the air
conditioner.
7 Ensure the live wire, neutral wire and
earth wire in the power socket are properly
connected.
8 Inadequate or incorrect electrical connections
may cause electric shock, fire or some
electrical parts to malfunction.
9 before performing any electrical work, turn off
the main power to the system.
Earthing Requirements
1 Air conditioner is type I electric appliance. The
unit must be reliably earthed and connected
to the special earth device by the qualified
electrician.
Circuit
Breaker
10A
16A
25A
25A
17