Type
Main Supply
Voltage
Current type
Connected load
Protection (slow, char. C)
Type of protection
Water connection
Max. feed temperature
Min. feed volume
Suck height from open container
(20 °C)
Max. feed pressure
Performance data
Working pressure
Nozzle size
Max. operating over-pressure
Water flow rate
Max. recoil force of trigger gun
Values determined as per EN 60335-2-79
Hand-arm vibration value
Uncertainty K
Sound pressure level L
Uncertainty K
pA
Sound power level L
Dimensions and weights
Length
Width
Height
Typical operating weight
Technical specifications
V
Hz
A
kW (hp)
A
°F (°C)
GPM (l/
min)
ft (m)
PSI (MPa)
PSI (kPa)
--
PSI (MPa)
GPM (l/
min)
N
m/s
m/s
dB(A)
pA
dB(A)
dB(A)
WA
mm
mm
mm
lbs (kg)
ProHD
400 Ed
US
12
1,4 (1,9)
1300
(9000)
1,7 (6,4) 1,55 (5,9) 1,7 (6,4)
2
2
– 11
EN
ProHD
ProHD
400
600
CA
CA
120
1~ 60
11,5
12
1,3 (1,7)
1,4 (1,9)
15
IPX5
140 (60)
2,5 (9,5)
1,6 (0,5)
145 (1)
1200 (8300)
030
1885 (13)
14,76
2,1
0,7
69
3
85
351
312
904
45,2 (20,5)
13