Kohler K-1663 Guia De Instalacion página 8

Ocultar thumbs Ver también para K-1663:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting Guide (cont.)
Symptoms
"Err 3" appears on the
3.
control pad.
"Err 4" appears on the
4.
control pad.
"Err 5" appears on the
5.
control pad.
"Err 6" appears on the
6.
control pad.
"Err 7" appears on the
7.
control pad.
8. "Err 8" appears on the
control pad.
9. Unit shuts off.
10. No steam is being
generated.
11. There is a continuous
flow of water from the
steam head. Water flow
during automatic purge
cycle is normal.
1008020-2-D
Probable Causes
A. "Down button" is stuck.
A. "Time" button is stuck.
A. The float switch was tripped for
10 seconds. The generator is not
getting enough water.
B. Water feed assembly is blocked.
C. Water supply to generator is
shut off.
A. The maximum heat has been
exceeded.
A. "Temperature" button is stuck.
A. "Clock" button is stuck.
A. Unit has been in operation for
more than 60 minutes. The unit
will time out.
A. Piping (inlet and outlet) is not
properly attached.
B. Steam head is blocked.
A. Water supply incorrectly
attached to steam generator.
B. Water feed assembly is stuck.
Recommended Action
A. Reset the power at the breaker.
A. Reset the power at the breaker.
A. Check the water supply for proper
flow and check that the water
supply to generator is turned on.
B. Remove and inspect the water feed
assembly in the generator.
C. Check for a clogged water line and
check that the water supply to
generator is turned on.
A. Shut off the system and allow it to
cool. Reset the power at the
breaker.
A. Reset the power at the breaker.
A. Reset the power at the breaker.
A. Turn unit back on.
A. Reattach the pipes properly.
B. Remove the steam head (after
cooling) and check that the plunger
slides freely in the cap.
A. Connect the water supply to the
proper inlet.
B. Remove and inspect the water feed
assembly in the generator.
8
Kohler Co.

Publicidad

Tabla de contenido
loading

Tabla de contenido