What to do if...?

The pump head cannot be correctly fitted
Cause
One or more filter baskets are overfilled or not
positioned correctly on top of one another
Intake openings at pump head and combi filter
basket II are not properly seated over each other
Filter on pump head leaks
Cause
Locking clips not closed or incorrectly closed
Profile seal is dirty
Canister seal is fitted incorrectly, twisted,
damaged or missing.
Leakage does not occur until after startup
procedure, usually at the clips.
Filter does not run or no water flows out
Cause
No power supplied
No water in the filter
Impeller and/or shaft fitted crooked, shaft broken,
rubber bearings of shaft missing, bayonet lock on
impeller casing not positioned correctly
Faulty or missing impeller. Impeller blocked by
gravel or snail shells
Flow rate greatly reduced
Cause
One or both stopcock levers on the pump head
not in "OPEN" position"
Hose connection block dirty
Hoses kinked, etc.
Intake strainer clogged
Hoses blocked with deposits
Filter media heavily soiled
28
Solution
Do not overfill filter baskets, check that the
baskets are properly stacked on top of each other.
Turn pump head or combi filter basket II 180°.
Solution
Close all locking clips correctly
Clean sealing surfaces and grease with petroleum
jelly (e.g. Vaseline)
Position the seal correctly or replace
Seal inside the hose connection block is
damaged. Change hose connection block.
Solution
Plug into power supply
The filter is not self-priming! Press start button
and fill filter with water (5)
Dismantle, check, replace faulty parts and re-
assemble. Check that shaft and bayonet lock are
correctly positioned.
Clean the impeller casing, fit an intact impeller
Solution
Check and correct lever position
Remove hoses and use a suitable brush to clean
the hose connection block, when installed
correctly, with the stopcock levers in "OPEN"
position
Check hoses for kinks, constrictions, etc.
Clean the intake strainer
Clean hoses with cleaning brush
Clean the filter media (particularly the pre-filter
media).