Place the ceramic shaft and impeller back in the casing. Check that both rubber
bearings are correctly positioned for the ceramic shaft. Place the impeller cover back
and, pressing gently, turn the cover towards "CLOSE" until the stop point.
11
Re-starting filter
Place the hose connection block with the attached hoses back in position as described
in (2). Then turn the right-hand stopcock lever followed a few seconds later by the left-
hand one towards "OPEN" until the stop point.
If the water does not begin to run into the filter automatically, start the filter as
described in (5).
Connect the filter to the mains power.

What to do if...?

The pump head cannot be correctly fitted
Cause
One or more filter baskets too full or not
positioned correctly on top of one another
Filter on pump head leaks
Cause
Fastening clips not closed or not properly closed
Profile seal washer dirty
Profile seal washer fitted incorrectly, twisted,
damaged or missing.
Filter does not run or no water flows out
Cause
No power supplied
No water in the filter
Impeller and/or shaft fitted crooked, shaft broken,
rubber bearings of shaft missing, bayonet lock on
impeller casing not positioned correctly
Impeller missing or blocked by gravel, wormgear
casing or impeller faulty
Filter capacity greatly reduced
Cause
Stopcocks levers on pump head not in "OPEN"
position
22
Solution
Do not overfill filter baskets, check the baskets
are properly stacked on top of each other
Solution
Close all fastening clips correctly
Clean sealing surfaces and grease with Vaseline
Position seal washer correctly or replace
Solution
Plug into power supply
Filter does not have automatic suction! Press start
button and fill filter with water (5)
Dismantle, check, replace faulty parts and re-
assemble. Check shaft and bayonet lock correctly
positioned.
Clean impeller casing, fit intact impeller
Solution
Check positions and correct them