Caring For And Cleaning Your Appliance; Changing And Cleaning The Anti-Grease Filters; Installing The Carbon Fi Lter; Changing The Light Bulb - Brandt AD1578X Manual De Utilización

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1

4 / CARING FOR AND CLEANING YOUR APPLIANCE

• CHANGING AND CLEANING THE ANTI-GREASE FILTERS

— Removing the fi lters as the instruction in Pic. 8;
— Open: Open the panel and drive up, push the
middle of hinge (see point A) at the same time, the
panel can be supported up.
— Close:Put up the panel a little (see point B) and
then the panel can be closed.
— You can clean the fi lter as below measure:
1. Soak them for about 3 minute in hot water (40-
50 degrees) with a grease-loosening detergent
then brush it gently with a soft brush. Please do
not apply too much pressure, avoid damaging
it.
2. It can be put into a dishwasher with detergent,
set the temperature at around 60 degrees.
— Please do not use abrasive detergent for it will
damage the hood;
— Make sure that the hood is shut off before
cleaning.
• INSTALLING THE CARBON FILTER, SEE PIC. 9;
— Remove the fi lters.
— The charcoal fi lters are located at either end of
the motor. Turn the charcoal fi lters anti-clockwise
until they are unscrewed.
— Apply reverse procedure to uninstall the charcoal
fi lter.
Warning:
the charcoal cannot be washed or recycled. It
should be changed at least every four months.

• CHANGING THE LIGHT BULB

Take the bracket and glass off and then take
the broken light bulb off, See Pic 10.
Fix the new light bulb,glass and bracket on.
Attention:Before changing the lights, ensure
that the appliance is not live.
29
EN
Pic 8
Open
Close
Pic 9
Pic 10

Publicidad

Tabla de contenido
loading

Tabla de contenido