Troubleshooting - Water Ace R100U Manual Del Usuario

Bomba para todo uso/ de transferencia
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2. Replace all fill plugs.
3. Power on! Start the pump. If you don't have water after 2
or 3 minutes, stop the pump and remove the fill plugs.
Refill the pump and piping. You may have to repeat this
several times in order to get all of the trapped air out of
the piping. A pump lifting water 25' may take as long as
15 minutes to prime.
4. After the pump has built up pressure in the system and
shut off, check the pressure switch operation by opening a
faucet or two and running enough water out to bleed off
pressure until the pump starts. The pump should start
when the pressure drops to 30 PSI and stop when the
pressure reaches 50 PSI. Run the pump through one or two
complete cycles to verify correct operation. This will also
help clean the system of dirt and scale dislodged during
installation.

TROUBLESHOOTING

SYMPTOM
POSSIBLE CAUSE(S)
Motor will not run
Fuse is blown or circuit breaker tripped
Motor runs hot and
Voltage is too low
the overload kicks
off or the does not
run and only hums.
Motor runs but no
Pump during new installation did
water is delivered*
not pick up prime through:
1. Improper priming
2. Air leaks
* (Note: Stop pump;
then check prime
before looking for
3. Leaking foot valve
other causes. Unscrew
4. Pipe size is too small
priming plug and see
Pump has lost prime through:
if water is in priming
1. Air leaks
hole).
2. Water level below suction pipe inlet
Impeller is plugged
Foot valve is stuck shut
Pipes are frozen
Foot valve and/or strainer are
buried in sand or mud
*Pump does not
Water being pumped is lower than
deliver water to full
estimated
capacity
Steel piping (if used) is corroded or
limed, causing excess friction
Piping is too small in size
Pump not being supplied with
enough water
Congratulations on a successful installation.
If you were unsuccessful, please refer to the
Troubleshooting section (below) or call our
consumer hotline at 1-800-942-3343.
CORRECTIVE ACTION
DISCONNECT POWER;Replace fuse or reset circuit breaker.
Check voltage being supplied to the pump.
In new installation:
1. Re-prime according to instructions.
2. Check all connections on suction line, with soapy water or
shaving cream.
3. Replace foot valve.
4. Re-pipe using size of suction and discharge ports on pump.
In installation already in use:
1. Check all connections on suction line and shaft seal with soapy water.
2. Lower suction line into water and re-prime. If receding water level
in well exceeds 25' (7.6M), a deep well pump is needed.
Clean impeller.
Replace the foot valve.
Thaw pipes.
Raise the foot valve and/or strainer above bottom of water source.
Clean foot valve and strainer.
A deep well jet will may needed if the water being pumped is more than
25' (7.6M) depth to water.
Replace with plastic pipe where possible, otherwise with new steel pipe.
Re-pipe using size of suction and discharge ports on pump.
Add additional well points.